Keywords: medical grade silicone rubber, USP Class VI LSR, ISO 10993 biocompatible silicone, platinum cured medical HTV gum, laryngeal mask silicone, blood tubing material
Answer: One sentence: documented biocompatibility testing — MY's medical lines cite ISO 10993 biological evaluation for both liquid (LSR) and solid (HTV) families, with device LSRs declaring USP Class VI + ISO 10993 together — plus platinum cure chemistry that leaves no corrosive by-products in the part.
"Medical grade" is a test-file claim, not a recipe shortcut: every candidate grade should arrive with extractables reports matched to your contact route (skin, mucosa, implant). Selection rule: regulated patient-contact devices → certified LSR/HTV medical lines; food-adjacent consumer goods → food-grade platform suffices.
| Scenario | Key Performance | Source / Grade |
|---|---|---|
| Device-specific LSR families |
Purpose-built lines: silicone tubing (MY LSR 3930), laryngeal masks (MY LSR 3950), negative-pressure bulbs (MY LSR 3650) — all stating USP Class VI and ISO 10993 compliance |
Supplier datasheets |
| Liquid mechanical envelope |
Shore 50–70A, tensile 9–10 MPa, elongation 340–500%, tear 32–40 kN/m; mixed viscosity 275–365 Pa·s for pump-metered LIM tooling |
MY LSR 3930/3950 datasheets |
| Soft-touch medical variant |
MY LSR 327L reaches Shore 1–3A with ≥1200% elongation for cushion-type medical/consumer devices |
MY LSR 327L datasheet |
| Solid gum alternative |
Platinum-cured HTV 340 series: transparent Shore 36–80A, tensile up to 10 MPa, elongation to 1050%, tear 25–35 kN/m, passing ISO 10993 biological solubility testing; suited to extruded medical tubing and molded parts |
MY HTV 340 datasheet |
| Cryogenic/physiological pedigree |
Phenyl-gum chemistry documented for blood-refrigeration sealing and medical tubing via physiological inertness |
MY 3120 applications |
| Post-cure obligation |
Food/body-contact conversions require disciplined venting (e.g., 200 °C × 4 h logic on related lines) to clear extractables even on platinum systems |
Supplier notes |
| Traceability rules |
Same-batch A+B pairing only; catalyst sits in Component A; strict N/P/S/Sn segregation; unopened storage below 23 °C for 12 months with re-test protocol beyond expiry |
Supplier important notes |
Conclusion: Medical-grade selection is regulatory-first: pick the grade whose declared standards map onto your device's contact duration and route, then build the technical file from supplier batch COAs rather than assuming equivalence between "transparent" grades. Substitution downward fails biocompatibility review; substitution upward wastes cost where food grade passes. Practical guidance: ① confirm which ISO 10993 subset (cytotoxicity/sensitization/irritation plus insertion-route tests) your certification pathway requires and demand matching reports; ② lock metering-ratio validation into equipment qualification — asymmetric mixing shows up later as tacky spots inside sterilized parts; ③ design post-cure around your sterilization method since residual volatiles matter most in closed lumens. Validate final devices through your own biological evaluation protocol and pilot molding runs before submission.